Multiquip GB2000 Work Light User Manual


 
PAGE 24 —GB2000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV. #3 (08/30/12)
LAMP ADAPTER PLATE MOUNTING INSTALLATION
1. Remove the adapter plate kit hardware from its
container.
2. Before proceeding make sure the light tower mast is
in the stow position (down) and the cradle lock/release
pin has been inserted and the mast is locked.
3. Attach the lamp adapter plate to the T-Bar as shown in
Figure 18. Align adapter plate so that adapter spacer
notch fits over screw on T-Bar. Please pay close
attention to the orientation of the 2 support brackets.
4. Mount the flat end of both support brackets flush
against the T-Bar with the low end of each bracket
facing inward toward the mast. The raised end of each
bracket should be facing outward.
TYPE 2 SETUP (S/N G1900119 AND ABOVE)
5. Next, insert a bolt (4) and flat washer (4) thru the
mounting holes on the the adapter plate as shown in
Figure 18. Again, pay close attention on which set of
holes to insert the bolt thru. Bolt number 2 must be
oriented so that it passes between receptacles J1 and
J2 on the T-Bar.
6. Secure the adapter plate to the T-Bar using the supplied
flat washer (4), lock washer (4) and nut (4). Make sure
the adapter plate is level (use a bubble level) and both
brackets are straight (vertical), not slanted before
tightening
NOTICE
Please pay close attention to the orientation of the 2
support brackets. Each bracket has a high and low side.
the low side of the bracket should be facing inwards
towards the mast.