12
W415-0689 / 06.25.08
O
S
A
A. This appliance is equipped with an ignition device which
automatically lights the burner. Do not try to light by hand.
B. Before operating, smell all around the appliance area for
gas and next to the fl oor because some gas is heavier than
air and will settle on the fl oor.
C. Do not use this appliance if any part has been under water.
Immediately call a qualifi ed service technician to inspect the
appliance and replace any part of the control system and any
gas control which has been under water.
• Turn off all gas to the appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use a mobile or
land phone.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fi re
department.
1. STOP! Read the safety information located above.
2. Turn off all electric power to the appliance.
3. This appliance is equipped with an ignition device which
automatically lights the burner. Do not try to light by hand.
4. Remove the glass door.
5. Wait fi ve (5) minutes to clear out any gas. If you smell gas
including near the fl oor STOP! Follow “B” in the above safety
information on this label. If you don’t smell gas go to the next
step.
6. Replace the glass door.
7. Turn on all electric power
to the appliance.
8. Turn the appliance
switch to the ON position.
9. If appliance will not
operate, follow instructions
“To Turn Off Gas” and call
your service technician or
gas supplier.
FOR YOUR SAFETY READ BEFORE LIGHTING:
LIGHTING INSTRUCTIONS
WHAT TO DO IF YOU SMELL GAS:
FIGURE 18
OPERATING INSTRUCTIONS
1. Turn the appliance switch to the OFF position.
2. Turn off all electrical power to the appliance if service is to
be preformed.
3. Turn manual shut-off valve clockwise to off.
Do not force.
TO TURN OFF GAS
RATING PLATE
RATING LABEL LOCATION:
The rating label is located under
the control panel and is chained to
the appliance.
DO NOT REMOVE.
CERTIFIED UNDER : CR97-003-M85, IAS US 4-96 OUTDOOR GAS FIREPLACE
IF APPLIANCE HAS BEEN SUPPLIED WITH A GAS PRESSURE REGULATOR, IT MUST BE USED. THE
GAS SUPPLY MUST BE TURNED OFF AT THE LP-GAS SUPPLY CYLINDER WHEN THIS APPLIANCE IS
NOT IN USE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE. IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO
THE OWNER’S MANUAL PROVIDED WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL
INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR GAS SUPPLIER. MUST
NOT BE USED FOR COOKING. FOR OUTDOOR USE ONLY. IF STORED INDOORS, DETACH AND
LEAVE CYLINDER OUTDOORS.
I
N
T
E
R
T
E
K
W
a
r
n
o
c
k
H
e
r
s
e
y
CM
CUS
ALTITUDE
INPUT
ORIFICE
MANIFOLDPRESSURE:3.5"WATER COLUMN
MINIMUMSUPPLYPRESSURE:4.5"WATER COLUMN
MAXIMUMSUPPLYPRESSURE: 7.0"WATERCOLUMN
MANIFOLDPRESSURE:10" WATERCOLUMN
MINIMUMSUPPLYPRESSURE:11"WATERCOLUMN
MAXIMUMSUPPLYPRESSURE:13" WATERCOLUMN
0-4500FT(0-1370m)
6,000BTU/h
#69
0-4500FT(0-1370m)
6,000BTU/h
#56
CERTIFIED FOR CANADA AND USA
GSST8N
MODEL
GSST8P
MODEL
W385-0420
GSST8
NOT FOR USE WITH SOLID FUEL. FORUSE WITH
GLASSDOOR. CERTIFIED WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
TOP 18” BACK 0”
SIDES 1” FLOOR 8”
MADEINCANADA
WOLFSTEELLTD,BARRIE, ON,CANADA
SERIALNUMBER:
ELECTRICAL RATING: 115v 0.82AMP, 60HZ
REFERENCE
# W/N 16036
TOP, SIDES & BACK AS PER ABOVE. FOR FINISHING
MATERIAL, SEE OWNERS MANUAL.
(NATURAL GAS)
(PROPANE)
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE
OF GAS INDICATED ON THE RATING PLATE. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH
OTHER GASES, UNLESS A CERTIFIED KIT IS USED.
After extended periods of non-operation such as following
a vacation or a warm weather season, the fi replace may
emit a slight odour for a few hours. This is caused by
dust particles burning off.
Always shut off the fi replace, gas to the fi replace and
allow the fi replace to cool before servicing it.
If the appliance keeps shutting off, have it serviced. Keep
burner and control compartment clean.
When lit for the fi rst time, the fi replace will emit a slight
odour for a few hours. This is a normal temporary
condition caused by the curing “burn-in” of internal
paints and lubricants used in the manufacturing process
and will not occur again.