Oki C5510 Air Compressor User Manual


 
22- ENG
A10260
To Replace Regulator
1. Release all air pressure from air
tank. See "To Drain Tank" in the
"Maintenance" section.
2. Set the On/Auto/Off lever to "Off"
and unplug unit.
3. Using an adjustable wrench remove
the outlet pressure gauge and quick
connect from the regulator.
4. Remove the regulator.
5. Apply pipe sealant tape to the nipple on the standpipe.
6. Assemble the regulator and orient as shown.
NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of
air flow.
7. Reapply pipe sealant to outlet pressure gauge and quick connect.
8. Reassemble outlet pressure gauge and quick connect. Orient outlet
pressure gauge to read correctly. Tighten connect with wrench.
Outlet Pressure Gauge
Quick
Connect
Regulator
Regulator
Nipple
Regulator
Arrow