3 DISASSEMBLY/ASSEMBLY INSTRUCTIONS
Ref. No. 1A Procedure 1A Removal and attachment of the Housings.
1. Loosen the belt hook bolt turning it counterclockwise, using a
coin or a flat blade screwdriver.
2. Take out the belt hook.
3. Remove nine housing screws.
4. Open the housing B.
NOTE :
The housing A and B is tightened as the motor mounting base
is joint fitting.
Hold the housing B and take it out vertically.
5. Take out the fixation cover, protectors and anvil block.
(Removal)
NOTE :
When opening the housings, make sure that the main PCB is
on the housing A.
If the main PCB sticks in the housing B and pull it out from the
housing A, the ribbon cable may be defected.
3