OnSite 2621 & 2635 Quick Start Guide 3
1.3 Models with internal DC power supply
1. Strip insulation 1/4-inch from the electrical wires that will connect the DC power source to the OnSite.
2. Connect the ground terminal from the power source to the ground terminal on the OnSite.
3. Connect the negative (-) terminal from the power source with to the negative (-) terminal on the OnSite.
4. Connect the positive (+) terminal from the power source with to the positive (+) terminal on the OnSite.
1.4 Power-up indication
The Power LED blinks as the OnSite is powering up. When the Power LED stops blinking and remains lit, the
OnSite is ready for you to configure.
2.0 Configure the IP address
The OnSite is shipped with a factory-configured IP address assigned to the Ethernet LAN port (green outline). The
address is 192.168.200.10/24. In most cases, you must change the address to be on the same subnet as your
PC, as described in the procedures below. If you are not sure which IP address to use for your installation, contact
your network administrator.
2.1 Connect a PC and log in
1. Using the included combination RS232/Ethernet cable and DB9-RJ45 adapter, connect a PC’s serial port
to the OnSite’s Console port (see figure 1).
Figure 1. Connecting OnSite to the PC’s serial port
2. Start a HyperTerminal session on the PC using the settings:
9600 bps, 8 data bits, 1 stop bit, no parity, no flow control
3. Log in to the OnSite using the factory-default login and password:
Login: superuser
Password: superuser
Login successful
Link
Frame
TD
RD
Link
100M
Tx
Rx
WAN
Ethernet
Power
Console
ipLink Gateway
High Speed WAN Access Router
Model 2603
Connect to Console port
Serial port
PC with
terminal emulator