Pioneer PX-42XM3 Work Light User Manual


 
34
35. INVERSE Set
Function
The external control equipment sets the INVERSE (inverse of image
brightness) and the WHITE of the plasma monitor.
Transmission Data
DFH 80H 60H C7H 03H DATA00 DATA01 DATA02 CKS
DATA00: INVERSE/WHITE 00H : No operation
01H : ON (INVERSE)
02H : OFF
03H : WHITE
DATA01 : WORKING TIME 00H : ON
01H: 03M (minutes)
02H: 06M (minutes)
:
FFH: 12H (hours) and 45M (minutes)
DATA02 : WAITING TIME 01H: 03M (minutes)
02H: 06M (minutes)
:
FFH: 12H (hours) and 45M (minutes)
ACK
3FH 60H 80H C7H 00H CKS
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes.
Example: 03H=9 minutes
1EH=1 hour and 30 minutes