Pioneer PX-42XM3 Work Light User Manual


 
49
50. D-SUB INPUT
Function
The external control equipment sets the D-SUB SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 8DH 01H DATA00 CKS
DATA00 : D-SUB INPUT 01H : RGB
02H : SCART3(*:Only Europe can be chosen.)
ACK
The plasma monitor returns the following ACK when setting the D-SUB
SELECT:
7FH 60H 80H 8DH 01H DATA00 CKS
DATA00 : D-SUB INPUT 01H : RGB
02H : SCART3(*:Only Europe can be chosen.)
51. TIMER SWITCH
Function
The external control equipment sets the timer reservation of the plasma
monitor.
Transmission Data
DFH 80H 60H 02H 01H DATA00 CKS
DATA00: 00H : Reservation OFF
01H : Reservation ON
ACK
7FH 60H 80H 02H 01H DATA00 CKS
DATA00: 00H : Reservation OFF
01H : Reservation ON