Pioneer PX-50XM4 Work Light User Manual


 
20
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag 01H
DATA01 : TINT Gain Flag 05H
12. PICTURE MODE Select
Function
The external control equipment sets the picture mode of the plasma monitor.
Transmission Data
DFH 80H 60H 0AH 01H DATA00 CKS
DATA00: 01H : NORMAL
02H : THEATER1(It cannot choose in the still picture input of a
personal computer.)
03H : THEATER2(It cannot choose in the still picture input of a
personal computer.)
04H : Default
05H : Bright
ACK
7FH 60H 80H 0AH 01H DATA00 CKS
DATA00: 01H : NORMAL
02H : THEATER1
03H : THEATER2
04H : Default
05H : Bright
13. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma
monitor.
Transmission Data
DFH 80H 60H 00H 01H DATA00 CKS
DATA00 : 00H: low
01H: middle
02H: high
03H: middle low