Pioneer PX-50XM4 Work Light User Manual


 
21
ACK
7FH 60H 80H 00H 01H DATA00 CKS
DATA00 : 00H: low
01H: middle
02H: high
03H: middle low
14. RED Gain Data
Function
The external control equipment changes the RED Gain Data of the plasma
monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag 01H
DATA01 : RED Gain Flag 01H
DATA02 : RED Gain1(Bias) D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
DATA03: RED Gain2(Drive) D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag 01H
DATA01 : RED Gain Flag 01H