Pioneer PX-50XM4 Work Light User Manual


 
62
61. POWER DELAY ON(at 4 or 9 multiscreen)
Function
External control apparatus attaches a time lag to two or more plasma
monitors, and turns on a power supply.
Transmission Data
DFH 80H 60H F2H 01H DATA00 CKS
DATA00: 00H-FFH: Delay time (second)
*: This command is premised on two or more plasma monitor system
composition being multi-systems. In command issue of master
1
OSD operation,
the value of DATA00 is 01H (1 second). This command does not have ACK for
one-way traffic.
*1: “Master” means the 1st set of PDP at the time of cable connection at
the time of AUTO ID execution.
62. POWER DELAY ON (at 16 or 25 multi screens)
Function
External control apparatus attaches a time lag to 10 or more plasma monitors,
and turns on a power supply.
Transmission Data
DFH 80H 60H F6H 01H DATA00 CKS
DATA00: 01H mode1
02H mode2
ACK
7FH 60H 80H F6H 01H DATA00 CKS
DATA00: 01H mode1
02H mode2
NOTE: When multi mode is 16 or 25, this function is available.