15 - ENG 1000003145
6. Apply sealant to the check valve threads. Reinstall the check valve (turn clock-
wise).
7. Replace hose and new hose clamp.
8. Perform the Break-in Procedure. See "Break-in Procedure" in the Operation
section.
TO REPLACE REGULATOR
1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance
section.
2. Unplug unit.
3. Using an adjustable wrench remove
Safety
Valve
Regulator
Manifold
Quick
Connects
Gauges
the gauges, quick connect, and
safety valve from the regulator
manifold.
4. Remove the hose by removing the
hose clamp. NOTE: The hose clamp
is not reusable. You must purchase a
new hose clamp, see the Parts List
Manual or purchase a standard hose
clamp at a local hardware store.
5. Remove pump mounting screws
Pump
Mounting
Screw
Hose Clamp
securing pump (one on each side).
6. Carefully slide pump from brackets
and out of the way.
7. Using an adjustable wrench remove
the regulator manifold.
8. Apply pipe sealant to new regulator
manifold and assemble, tighten with
wrench.
9. Reapply pipe sealant to gauges,
quick connect, and safety valve.
10. Reassemble all components in
Pump shown
moved out of
the way
Regulator
Manifold
reverse order of removal. Make sure
to orient gauges to read correctly and
use wrenches to tighten all