Porter-Cable C6110 Air Compressor User Manual


 
16- ENG
TO REPLACE REGULATOR
1. Release all air pressure from air tank. See To Drain Tank in the Maintenance
section.
2. Set the Auto/Off lever to "Off" and unplug unit.
3. Using an adjustable wrench remove the outlet pressure gauge and quick con-
nect from the regulator.
4. Using an adjustable wrench loosen pressure relief tube nut at air tank. Carefully
move pressure relief tube away from check valve.
Regulator
Regulator
Nipple
Outlet Pressure
Gauge
Quick
Connect
Pressure
Relief Tube
5. Remove the regulator.
6. Apply pipe sealant tape to the nipple on the standpipe.
7. Assemble the regulator and orient as shown.
NOTE: Arrow indicates flow of air. Make sure it is pointing
Arrow
Regulator
in the direction of air flow.
8. Reapply pipe sealant to outlet pressure gauge and
quick connect.
9. Reassemble outlet pressure gauge, pressure relief
tube and quick connect. Orient outlet pressure gauge
to read correctly. Tighten quick connect with wrench.
STORAGE
Before you store the air compressor, make sure you do the following:
1. Review the Maintenance section on the preceding pages and perform
scheduled maintenance as necessary.
2. Drain water from air tank. See To Drain Tank under Maintenance.
Water will condense in the air tank. If not drained, water will
corrode and weaken the air tank causing a risk of air tank rupture.
3. Protect the electrical cord and air hose from damage (such as being stepped
onorrunover).Windthemlooselyaroundthecompressorhandle.
4. Store the air compressor in a clean and dry location.