Porter-Cable C7510 Air Compressor User Manual


 
21- ENG
D28176
SERVICE AND ADJUSTMENTS
Unit cycles automatically when power is on. When doing
Maintenance, you may be exposed to voltage sources,
compressed air or moving parts. Personal injuries can occur. Before
performing any Maintenance or repair, unplug the compressor and bleed
off all air pressure.
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE TECHNICIAN.
Before servicing:
Unplug or disconnect electrical supply to the air compressor.
Bleed tank of pressure.
Allow the air compressor to cool.
To Replace or Clean Check Valve
1. Release all air pressure from air tank. See “To Drain Tank” in the
Maintenance section.
2. Turn air compressor off, lock out the power supply, and relieve all air
pressure from the air tank.
3. Using an adjustable wrench loosen outlet tube nut at air tank and pump.
Carefully move outlet tube away from check valve.
4. Using an adjustable wrench loosen pressure relief tube nut at air tank and
pressure switch. Carefully move pressure relief tube away from check
valve.
5. Unscrew the check valve (turn counterclockwise) using a 7/8” open end
wrench. Note the orientation for reassembly.
6. Using a screwdriver, carefully push
the valve disc up and down. NOTE:
The valve disc should move freely
up and down on a spring which
holds the valve disc in the closed
position, if not the check valve
needs to be cleaned or replaced.
7. Clean or replace the check valve. A
solvent, such as paint or varnish
remover can be used to clean the
check valve.
8. Apply sealant to the check valve threads. Reinstall the check valve (turn
clockwise).
9. Replace the pressure release tube. Tighten nuts.
10. Replace the outlet tube and tighten nuts.
11. Perform the Break-in Procedure. See “Break-in Procedure” in the
Operation section.
In closed position
disc is visible.
In open
position
nothing is
visible.
Screwdriver