Porter-Cable CPFAC2600P Air Compressor User Manual


 
8 - ENG
D27856
GLOSSARY
SCFM or CFM: Standard Cubic Feet per Minute; a unit of measurement of air
delivery.
PSIG or PSI: Pounds per square inch gauge.
CUT-IN PRESSURE: While the motor is off, air tank pressure drops as you
continue to use your accessory or air tool. When the tank pressure drops to a
certain low level the motor will restart automatically. The low pressure at which
the motor automatically restarts is called “cut-in pressure.”
CUT-OUT PRESSURE: When you turn on your air compressor and it begins to
run, air pressure in the air tank begins to build. It builds to a certain high pressure
before the motor automatically shuts off - protecting your air tank from pressure
higher than its capacity. The high pressure at which the motor shuts off is called
“cut-out pressure.”
CODE CERTIFICATION: Products that bear one or more of the following marks:
UL, CUL, ETL, CETL, have been evaluated by OSHA certified indepenent safety
laboratories and meet the applicable Underwriters Laboratories Standards for
Safety.
DUTY CYCLE
Porter-Cable air compressors should be operated on not more than a 50% duty
cycle. This means an air compressor that pumps air more than 50% of one hour
is considered misused, because the air compressor is undersized for the required
air demand. Maximum compressor pumping time per hour is 30 minutes.
SPECIFICATIONS
MODEL NO. CPFAC2600P
Horsepower-Peak 2.0
SCFM @ 40 psig 3.7
SCFM @ 90 psig 2.6
Cut-In 120 PSI
Cut-Out 150 PSI
Bore 1.875"
Stroke 1.250"
Voltage/Hertz/Phase 120/60/1
Minimum Branch Circuit 15 Amp
* Fuse Type Time Delay
Amperage at Max. Load 10 Amps
Tank Size 6 Gallon
* A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same
rating as the branch circuit on which the air compressor is operated. If
compressor is connected to a circuit protected by fuses, use only time delay
fuses. Time delay fuses should be marked “D” in Canada and “T” in the US.