Handles
1. Remove the plate (V) from the handle (U) by
loosening the two socket head cap screws
(W) with a 6mm hex wrench.
2. Install handle (U) to the holes in the collector
housing (S) by inserting the socket head cap
screws through the handle, the collector
housing, and into the plate on the opposite
side. Tighten the screws.
Note: Make sure the plate (V) is oriented
properly, as shown in the Detail in Figure 3:
The protrusions on the plate should face
away from the handle.
3. Install the second handle to the housing.
Cone Installation
Install the cone assembly as shown in Figure 3a.
1. Mount the cone support bracket (AA) to the
housing with four M6x12 hex cap screws (FF)
and tighten from beneath with four M6 hex
nuts (GG).
2. Install the cone (BB) from beneath using the
M8x16 hex cap screw (CC), M8 flat washer
(DD) and M8 hex nut (EE).
Filter System
If your PM1300TX Dust Collection system includes
filter bags, proceed to Filter Bag System Assembly
on page 10.
If your PM1300TX Dust Collection system includes
the canister kit, proceed to Canister System
Assembly on page 11.
Figure 3: Assembly and hardware identification