Python 232-835 Welder User Manual


 
Python
®
Lincoln Compatible
Owner's Manual - Page ii
using protective equipment.
Water-lling just below working level may
substitute for inerting.
A container with unknown contents
should be cleaned (see paragraph
above). Do NOT depend on sense of
smell or sight to determine if it is safe to
weld or cut.
Hollow castings or containers must be
vented before welding or cutting. They
can explode.
Explosive atmospheres. NEVER weld
or cut where the air may contain am-
mable dust, gas, or liquid vapors (such
as gasoline).
D. Compressed Gas Equipment
The safe handling of compressed gas
equipment is detailed in numerous indus-
try publications. The following general
rules cover many of the most common
situations.
1. Pressure Regulators
Regulator relief valve is designed to
protect only the regulator from overpres-
sure; it is not intended to protect any
downstream equipment. Provide such
protection with one or more relief devices.
Never connect a regulator to a cylinder
containing gas other than that for which
the regulator was designed.
Remove faulty regulator from service
immediately for repair (rst close cylinder
valve). The following symptoms indicate
a faulty regulator:
Leaks - if gas leaks externally.
Excessive Creep - if delivery pressure
continues to rise with downstream valve
closed.
Faulty Gauge - if gauge pointer does not
move off stop pin when pressurized, nor
returns to stop pin after pressure release.
Repair. Do NOT attempt repair. Send
faulty regulators for repair to manufac-
turer’s designated repair center, where
special techniques and tools are used
by trained personnel.
2. Cylinders
Cylinders must be handled carefully to
prevent leaks and damage to their walls,
valves, or safety devices:
Avoid electrical circuit contact with cylin-
ders including third rails, electrical wires,
or welding circuits. They can produced
short circuit arcs that may lead to a seri-
ous accident. (See 1-3C)
ICC or DOT marking must be on each
cylinder. It is an assurance of safety
when the cylinder is properly handled.
Identifying gas content. Use only cylin-
ders with name of gas marked on them;
do not rely on color to identify gas con-
tent. Notify supplier if unmarked. NEVER
DEFACE or alter name, number, or other
markings on a cylinder. It is illegal and
hazardous.
Empties: Keep valves closed, replace
caps securely; mark MT; keep them sepa-
rate from FULLS, and return promptly.
Prohibited use. Never use a cylinder or its
contents for other than its intended use,
NEVER as a support or roller.
Locate or secure cylinders so they cannot
be knocked over.
Passageways and work areas. Keep cyl-
inders clear of areas where they may be
stuck.
Transporting cylinders. With a crane, use
a secure support such as a platform or
cradle. Do NOT lift cylinders off the ground
by their valves or caps, or by chains, slings,
or magnets.
Do NOT expose cylinders to excessive heat,
sparks, slag, and ame, etc. that may cause
rupture. Do not allow contents to exceed
55 degrees C (130 degrees F.) Cool with
water spray where such exposure exists.
Protect cylinders, particularly valves from
bumps, falls, falling objects, and weather.
Replace caps securely when moving cyl-
inders.
Stuck valve. Do NOT use a hammer or
wrench to open a cylinder valve that cannot
be opened by hand. Notify your supplier.
Mixing gases. NEVER try to mix any gases
in a cylinder.
NEVER rell any cylinder.
Cylinder ttings should never be modied
or exchanged.
3. Hose
Prohibited use. Never use hose other
than that designed for the specied gas. A
general hose identication rule is: red for
fuel gas, green for oxygen, and black for
inert gases.
Use ferrules or clamps designed for the
hose (not ordinary wire or other substitute)
as a binding to connect hoses to ttings.
No copper tubing splices. Use only stan-
dard brass ttings to splice hose.
Avoid long runs to prevent kinks and abuse.
Suspend hose off ground to keep it from
being run over, stepped on, or otherwise
damaged.
Coil excess hose to prevent kinks and
tangles.
Protect hose from damage by sharp edges,
and by sparks, slag, and open ame.
Examine hose regularly for leaks, wear, and
loose connections. Immerse pressured
hose in water; bubbles indicate leaks
Repair leaky or worn hose by cutting area
out and splicing. Do NOT use tape.
4. Proper Connections
Clean cylinder valve outlet of impurities that
may clog orices and damage seats before
connecting regulator. Except for hydrogen,
crack valve momentarily, pointing outlet
away from people and sources of ignition.
Wipe with a clean, lintless cloth.
Match regulator to cylinder. Before con-
necting, check that the regulator label
and cylinder marking agree, and that the
regulator inlet and cylinder outlet match.
NEVER Connect a regulator designed for a
particular gas or gases to a cylinder contain-
ing any other gas.
Tighten connections. When assembling
threaded connections, clean and smooth
seats where necessary. Tighten. If con-
nection leaks, disassemble, clean, and
retighten, using properly tting wrench.
Adapters. Use a CGA adapter (available
from your supplier) between cylinder
and regulator, if one is required. Use
two wrenches to tighten adapter marked
RIGHT and LEFT HAND threads.
Regulator outlet (or hose) connections
may be identied by right hand threads
for oxygen and left hand threads (with
grooved hex on nut or shank) for fuel gas.
5. Pressurizing Steps:
Drain regulator of residual gas through
suitable vent before opening cylinder
(or manifold valve) by turning adjusting
screw in (clockwise). Draining prevents
excessive compression heat at high
pressure seat by allowing seat to open
on pressurization. Leave adjusting
screw engaged slightly on single-stage
regulators.
Stand to side of regulator while opening
cylinder valve.
Open cylinder valve slowly so that regu-
lator pressure increases slowly. When
gauge is pressurized (gauge reaches
regulator maximum) leave cylinder valve
in following position: for oxygen and inert
gases, open fully to seal stem against
possible leak; for fuel gas, open to less
than one turn to permit quick emergency
shut-off.
Use pressure charts (available from your
supplier) for safe and efcient recom-
mended pressure settings on regulators.
Check for leaks on rst pressurization
and regularly thereafter. Brush with soap
solution. Bubbles indicate leaks. Clean
off soapy water after test; dried soap is
combustible.
E. User Responsibilities
Follow all Safety Rules.
Remove leaky or defective equipment
from service immediately for repair. Read
and follow user manual instructions.
F. Leaving Equipment Unattended
Close gas supply at source and drain gas.
G. Rope Staging-Support
Rope staging-support should not be
used for welding or cutting operation;
rope may burn.
1-3 ARC WELDING
Comply with precautions in 1-1, 1-2, and
this section. Arc Welding, properly done,
is a safe process, but a careless operator
invites trouble. The equipment carries
high currents at significant voltages.
The arc is very bright and hot. Sparks
y, fumes rise, ultraviolet and infrared
energy radiates, weldments are hot,
and compressed gases may be used.
The wise operator avoids unnecessary
risks and protects himself and others
from accidents.