Quincy Compressor Air Compressor Air Compressor User Manual


 
11
3.1 B-10 Burner Setup
Boiler Model B10-3 B10-4 B10-5 B10-6
Burner Model BF-3 BF-3 BF-5 BF-5
Firing Rate
0.55
0.80 1.00 1.25
Insertion Depth
3.0”
3.0" 3.0" 3.0"
Nozzle
.4 X 80
.65 X 80 .85 X 60 1.00 X 60
Spray Pattern
W
W W W
Pump Pressure
180 psi
175 psi 150 psi 175 psi
Turbulator
2
3 2 3
Air Gate
3.2
4.7 3.4 5
BURNER MANUFACTURER Riello
BF3 and BF5
BURNER MANUFACTURER Heat Wise
Pioneer
Boiler Model B-13 B-14 B-15 B-16
Burner Model P-1 KFV* P-1 KA P-1 KA P-2 KA
Firing Rate
0.55 0.90 1.00 1.25
Insertion Depth
3.5” 3.5” 3.5” 3.5”
Nozzle
0.40 X 80 0.65 X 70 0.85 X 70 1.00 X 80
Spray Pattern
Solid Solid Semi Solid
Hollow
Pump Pressure
200 200 150
190
Head Setting
1 1 1 3.75
Air Setting
0 9.5 16.5 6
*120mm Fan Needed
BURNER MANUFACTURER Beckett
AFII - 150 (NEC 301, 302, 303) , NX (NEC 1101, 1102, 1103)
Boiler Model B10 - 4* B10 - 5*
Burner Model NEC - 301 NEC - 1101 NEC - 302 NEC - 1101 NEC - 303 NEC - 1103
Firing Rate
0.80 0.90 1.00 1.00 1.25 1.20
Insertion Depth
2.75” 6.0” 2.75” 6.0” 2.75” 6.0”
Nozzle
.65 X 60
o
.65 X 60
o
.85 X 60
o
.75 X 60
o
1.00 X 60
o
.90 X 60
o
Spray Pattern
hollow solid solid solid solid W
Pump Pressure
160 psi 180 psi 140 psi 180 psi 160 psi 180 psi
Head Type
6 slot 9 slot 6 slot 9 slot 9 slot 9 slot
Head Position
3 3 4 4 5 4.25
Air Setting
3 N/A 3.75 N/A 6 N/A
B10 - 6* B10 - 3*
NEC - 1102
0.55
3.5”
.40 X 60
o
hollow
180 psi
6 slot
1.25
N/A
* - These burners may not be used in Canada on Biasi equipment