Quincy Compressor Air Compressor Air Compressor User Manual


 
3.2 SG Burner Setup
Boiler Model SG-2 SG-3 SG-4
Burner Model BF-3 BF-5 BF-5
Firing Rate
0.65 1.00 1.30
Insertion Depth
5.0" 5.0" 5.0"
Nozzle
.55 X 70 .85 X 60 1.10 X 80
Spray Pattern
solid solid solid
Pump Pressure
145 psi 145 psi 145 psi
Turbulator
0 0 2
Air Gate
4.5 4.0 5.6
BURNER MANUFACTURER Riello
BF3 and BF5
BURNER MANUFACTURER Heat Wise
Pioneer
Boiler Model SG-2 SG-3 SG-4
Burner Model P-1 FV P-1 KA P-2 KA
Firing Rate
.65 1.00 1.30
Insertion Depth
3.5” 3.5” 3.5”
Nozzle
0.5 X 80 0.75 X 70 1.00 X 80
Spray Pattern
solid solid Semi Solid
Pump Pressure
200 200 200
Head Setting
6 3 3
Air Setting
12.0 11.5 11.5
12
Boiler Model SG-2* SG-3* SG-4*
Burner Model NEC - 1201 NEC - 1202 NEC - 1202
Firing Rate
0.65 1.00 1.30
Insertion Depth
3.5” 6.0” 6.0”
Nozzle
.50 X 60
o
.75 X 60
o
1.00 X 60
o
Spray Pattern
hollow solid solid
Pump Pressure
180 psi 180 psi 180 psi
Head Type
6 slot 9 slot 9 slot
Head Position 1.50 3.50 4.25
BURNER MANUFACTURER Beckett
NX (NEC 1201, 1202)
* - These burners may not be used in Canada on Biasi equipment