Schumacher INC-14825A Battery Charger User Manual


 
10
PROBLEM POSSIBLE CAUSE REASON/SOLUTION
The measured current is
much lower than what was
selected.
The charger reached the
maximum voltage and is
reducing the current.
No problem, this is a normal
condition.
BEFORE RETURNING FOR REPAIRS14.
When a charging problem arises, make certain that the battery is capable 14.1
of accepting a normal charge. Use a good battery to double check all
connections and the AC outlet for a full 120-volts.
When an UNKNOWN OPERATING PROBLEM arises, please read the 14.2
complete manual and call the customer service number for information
that will usually eliminate the need for return.
If the above solutions do not eliminate the problem or for information about troubleshooting
or replacement parts, call toll-free from anywhere in the U.S.A.
1-800-621-5485
7:00 am to 5:00 pm Central Time Monday thru Friday
SPECIFICATIONS15.
Electrical
NominalOperatingVoltage(VAC) 120
InputVoltageRange(VAC) 120 ± 10%
InputCurrent(Amax) 15 A
OutputPower(W) 1200
OutputCurrent(Amax) 25
OutputVoltage(VDCmax./maintain) 61.6 / 52.8
Mechanical
Case Steel with Baked Enamel Finish
Dimensions(inches) 11 L x 9½ W x 10 ¼ H
Weight 40 lbs
Connections
AC Power Input Cable 14 Gauge 9’ with NEMA 5.15 Plug
DC Power Output Adapters 8 Gauge 6’ with Polarized 50 Amp Quick
Connect Connector