Sears 919.15412 Air Compressor User Manual


 
Grounding Instr,JcUons
L_ i
IMPROPER GROUNDING CAN RESULT iN
ELECTRICAl. SHOCK. IN THE EVENT OF A
SHORT CIRCUIT, GROUNDING REDUCES
IHE RISK OF SHOCK BY PROVIDING AN
ESCAPE WIRE FOR THE ELECTRIC CUR-
RENT. THIS AIR COMPRESSOR MUST BE
PROPERLYGROUNDED.
1. The air compressortsequippedwltha cord having a
groundingwire with an _ppr_priate groundingplug.
The plugmust be usedwith an outletthat has been
installedand groundedin accordance wi_hall IocaI
codes and ordinances, The out_etmust have the
_aJ'_econfigurationas the plug. DO NOT USE AN
ADAPTER,
2, Do notmodify the plug1hathas been provided.!! it
does not tit the available outlet, the correct outlet
shoutdbe installedby a qualifiederectrician
3 inspectthe plugandcordbeforeeach use_Donotuse
ifthereare signsof damage,
RISK OF ELECTRICAL SHOCK, IF REPAIR-
ING OR REPLACING CORD OR PLUG, THE
GROUNDING WIRE MUST BE KEPT SEPA-
RATE FROM THE CURRENT.CARRYING
WIRES, NEVER CONNECT THE GROUND,
tNG WIRE TO A FLAT BLADE PLUG TER-
MINAL (THE GROUNDING WIRE HAS
INSULATION WITH AN OUTER SURFACE
THAT IS GREEN - WiTH OR WITHOUT YEL-
LOW STRIPES.)
if these grounding ine_ru_Uonsare not completely
unclerstood0orif In doubtas to whether[he compressor
is properlygrounO_d,havethe install=ioncheckedby a
qualifiedelectrlclan_
Ground
" Wire ""
GROUNDING ,,2" L..------J
PIN
120 vOltS,i5 amps
Break-In PrOc_ums
Serious damage moy _glt If_I'KIfoll_ing
break-in tnatructrono =r== not closely
followed.
Thisprocedureisonly _quir-ud the firstlime the=Jrcom-
preSSOriS putintoserwce,
1. Set the swlt_ OFFtAUTO lever tothe'OFF'
poetriespressure
2 Plug the.power c_ordinto the (;orrectbranc;h cimUit
receptacJe,
3 Turnthe regulatorc!oc.kw'L_,e,,openingit fulIy,to pre.
ventmr pressureI:_uz=o-up=nthe tanK,
4_Move *,heOFF!AUTO leverto "AUTO'. Th_ compres-
sorwltIstarL
5, Run _he compressorfor 10 minutes, Make surethe
rupegulatorIs openand them is no tank pressure build- ,_
6 After 10 rnin.utes,_ose t,heregultttorby lurningit
counter-c_oc:Kwise,f ne_urtankv_lIfill_ OJt-,outpres-
sure andlhanthe rno_r Will510p
OPERATING PROCEDURES
1, Beforeattaching aJrhose or accessories, make sure
the OFFtAUTO lever is set to "OFF" and the air
regulatorIs closed (Close it by turningit counter-
ClOCkWiSe)
2_At_chhOSe _ndaocessorfes.
WARNING
1"OOMUCH AIR PREgSURE CREATES A
HAZARDOUS RISK OF BURSTING, CARE-
FULLYFOLLOWSTEPS 3 AND 5 EACH TIME
THE COMPRF-_SOR IS USED.
.
COMPRESSED AIR FROM THE OUTFIT MAY
CONTAIN WATER CONDENSATION. DO
NOT SPRAY UNRLTERED AIR AT AN ITEM
Tl1AT GOULD B_ DAMAGED. SOMF AIR
OPERATED TOOLS OR DEVICES MAY
REQUIRE FILTERED AIR. READ THE
INSTRUCTIONS FOR THE AIR TOOL OR
DEVICE,
Checkthe manufacturer'sm_lmum preserve_ating
for air tools and accessories, "Theregulatoroutlet
pressuremustnever exceed the maximurnprB_$ure
_at]ng.