Woodstock W1815 Sander User Manual


 
-24-
Model W1815 (Mfg. Since 10/10)
SERVICE
Table Tilt Calibration
When the table is perpendicular to the sanding disc, the
scaleshouldread0˚.Ifnot,followthisprocedure.
Tools Needed:
Machinist's Square ..............................................1
Phillips Head Screwdriver .....................................1
To calibrate the table tilt, do these steps:
1. DISCONNECT MACHINE FROM POWER!
2. Using a try square or machinist’s square, set one
edge on the table surface and the other against the
face of the disc, as shown in Figure 19.
Note: This can be done with the sandpaper
installed, although it is somewhat more precise
without the sandpaper.
3. Loosen the lock handles and adjust the table angle
until it is perfectly perpendicular to the disc, then
tighten the lock handles while holding the table in
place.
4. Loosen the degree scale pointer, index the pointer
on0˚,thenretightenthescrew.
5. Recheck the scale accuracy with the square.
Figure 19. Squaring the table.