Stanley Black & Decker RD12 Drill User Manual


 
RD12 User Manual ◄ 15
TOOL PROTECTION & CARE
Make sure all couplers are wiped clean before con-
nection.
The hydraulic circuit control valve must be in the
OFF position when coupling or uncoupling hydraulic
tools. Failure to do so may result in damage to the
quick couples and cause overheating of the hydrau-
lic system.
Always store the tool in a clean dry space, safe from
damage or pilferage.
Make sure the circuit PRESSURE hose (with male
quick disconnect) is connected to the IN port. The
circuit RETURN hose (with female quick disconnect)
is connected to the opposite port. Do not reverse cir-
cuit ow. This can cause damage to internal seals.
Always replace hoses, couplings and other parts
with replacement parts recommended by Stanley
Hydraulic Tools. Supply hoses must have a mini-
mum working pressure rating of 2500 psi/172 bar.
Do not e×ceed the rated ow (see Specications) in
this manual for correct ow rate and model number.
Rapid failure of the internal seals may result.
Always keep critical tool markings, such as warning
stickers and tags legible.
NOTICE
In addition to the Safety Precautions found in
this manual, observe the following for equipment
protection and care.
Tool repair should be performed by e×perienced
personnel only.
Make certain that the recommended relief valves
are installed in the pressure side of the system.
Do not use the tool for applications for which it was
not intended.