XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style 35 of 36
6-3 Quick Start Guide –XSV Venturi Loader
Unpack all parts. Check for the following:
Conveying hopper with level sensor
Control and maintenance unit
Venturi assembly
Vinyl flexible hose
Compressed air hose
Operating instructions
Mount the conveying hopper using the flange provided on its base.
Mount the control module at a location that is readily accessible. Make sure
that the compressed air hose and level sensor cable are long enough to
reach the control module.
Connect the compressed air supply from the control module to the fitting
located on the material pick up wand.
Connect shop compressed air to the regulator on the control module.
Compressed air connection must be 70-90 psi (5-6 bar).
Plus the control module into the main power socket. Make sure that the
correct voltage is being used.
Adjust the level sensor to sense the material that is being conveyed into the
conveying hopper.
Maintain the unit as stated in Chapter 5 of this manual.