Thermo Products AH2-A Impact Driver User Manual


 
All installations and services must be performed by qualified personnel.
8
1. Determine the appropriate blower speed settings listed in tables below.
2. Set the blower motor speed to match air conditioning requirement, connect the red
wire(cooling tap) to the appropriate fan speed on the terminal strip located on the blower(see
Figure D).
3. Set the blower motor speed to match heating requirement, connect the orange wire(heating
tap) to the appropriate fan speed on the terminal strip located on the blower(see Figure D).
Figure D
Heating Tap Locations
Terminal Strip Speed
40,000 (btuh) 60,000 (btuh) 80,000 (btuh) 100,000 (btuh)
C White White White White
H
MH
ML
Orange
L Orange Orange Orange
Cooling Tap Locations
Terminal Strip Speed
2 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 Ton
C White White White White White White
H
Red
MH
Red Red Red
ML
Red
L Red