Wagner SprayTech AC 4600 Professional Paint Sprayer User Manual


 
23
AC 4600 Pro
B_02261
x
A
B
C
D
B_02702
OPERATING MANUAL
EDITION 06/2012 PART NO. DOC394871
5.4.4 CLEANING AIRCOAT NOZZLE
For disassembly and assembly of AirCoat nozzles see chapter 5.4.3.
The AirCoat nozzle (C) can be placed into a cleaning solvent which has been recommend-
ed by the paint manufacturer.
5.4.5 ELIMINATE NOZZLE CLOGGING
1. Relieve spray gun and unit pressure.
2. Secure gun with trigger safety catch.
3. Unscrew the union nut with nozzle guard (A).
4. Remove air cap (B).
5. Pull out the clogged nozzle (C) from the air cap (B), reverse it and replace it into nozzle
seal (D).
6. Fit the aircap (B) over the nozzle (C), ensuring that the location fl ats (X) are in line.
7. Fit the union nut with nozzle guard (A) over the air cap (B) onto the spray gun and
tighten by hand.
8. Switch the material pressure back on.
9. Turn the safety catch to the spraying position and briefl y pull trigger.
10. When the blockage has been fl ushed out secure the gun with safety catch.
11. Relieve spray gun and unit pressure.
12. Unscrew the union nut with nozzle guard (A).
13. Remove air cap (B) and reverse nozzle (C) again. Clean nozzle and replace on the nozzle
seal (D) in spray position.
14. Refi t air cap (B) on the nozzle (C).
Take care that the nozzle fi tted is correctly (see fl at side X).
15. Fit the union nut with nozzle guard (A) over the air cap (B) onto the spray gun and
tighten by hand.
16. Switch the material pressure and the air pressure back on.
Nozzle in „spray“ position