6.5 REPLACING THE NOZZLE SEAL
1. Finishing work and cleaning.
2. Relieve spray gun and unit pressure.
3. Secure gun with trigger safety catch.
4. Unscrew the union nut with nozzle guard (33).
5. Remove air cap (36) and nozzle (13).
6. Carefully release the nozzle seal (17) with the help of a screwdriver.
7. Fit new nozzle seal to valve housing (16).
8. Continue assembly in the reverse order.
CAUTION
Defective nozzle seal!
Material sprays into the air cap next to the nozzle
Risk of contamination
Do not clean the nozzle seal with sharp-edged objects.
Replace the nozzle seal if the sealing surface is damaged.