Xantrex Technology 30A24V Battery Charger User Manual


 
Operation
2–8 975-0401-01-01
Operating DC Loads
When the Truecharge™ 2 Battery Charger is operating, DC
loads such as fans and lights may vary in speed or intensity.
This is normal. The Truecharge™ 2 Battery Charger will not
harm any load connected to it as long as the load can
withstand the maximum voltage of 16 V.
Table 2-3
Battery Temperature Compensation Levels
Temperature
Selection
Recommended
for battery
temperature of:
Voltage added for temperature
compensation offset from 25 °C
Cold below 5 °C
(41 °F)
Flooded/PbCa/Gel 0.675
AGM 0.525
Warm between
5 and 30 °C
(41 and 86 °F)
Flooded/PbCa/Gel 0
AGM 0
Hot above 30 °C
(86 °F)
Flooded/PbCa/Gel -0.27
AGM -0.21