Xantrex Technology 30A24V Battery Charger User Manual


 
Troubleshooting
3–6 975-0401-01-01
Low Battery Temp
fault (< -25°C)
Check the batteries. Do not charge a frozen battery.
Charging a frozen battery may present a risk of
explosion. Check that the battery type and
temperature settings match the actual battery.
Allow the battery (or batteries) to warm up to a
temperature that is above freezing before charging.
See Appendix A, “Specifications”.
AC input out of range
Warning; 90–108 V
or 255–265 V
Change to a more stable AC power source and check
that the voltage and voltage frequency are within
acceptable operating range. See Appendix A,
“Specifications”.
AC input out of range
fault; <85V or >265V
Check AC connections. Change to a more stable AC
power source and check that the voltage and voltage
frequency are within acceptable operating range. See
Appendix A, “Specifications”.
Flashing LED Solid LED
Table 3-1
Interpreting Fault and Warning Indicators
Fault or Warning
Condition
Temp Fan AC Battery Fuse Charger Remote Fault
Solution