Xantrex Technology Xantrex Battery Monitor Battery Charger User Manual


 
16
If none of the above remedies help to solve your problem, contact
your local dealer for further help.
CHARGE BATTERY or
CHARGE BATTERY
FULL flashes
Charge battery full (equalize/
synchronize your battery with
the monitor)
Check the charged parameters
in Functions F02, F03 and F04
for possible incorrect settings.
State-of-charge and/or
time-to-go readout are
not accurate
Check if all current is flowing
through the shunt (the negative
terminal of the battery may only
contain the wire going to the
battery side of the shunt!).
Current sense leads from the
shunt are reversed.
Check battery capacity in
Function F01
Check CEF in Function F09
•Check Peukert Exponent in
Function F10
Check Battery temperature in
Function F11
Check Temperature coefficient
in Function F12
Display returns “- - - -” in
temperature readout
Connection with temperature
sensor is lost. Check for failed
connections and/or cable damage.
Battery voltage readout is
highly inaccurate
Check prescaler setting in Function
F16