CHAPTER 3: CONFIGURING THE V7111
The V7111 application software already resides in the device’s flash memory when it is
supplied (with factory default parameters). V7111 devices also include an Embedded
(integrally stored) Web Server.
Assigning the V7111 IP Address describes how to assign an IP address to the V7111. Basic
Control Protocol Parameters describes how to set up the V7111 with basic parameters using
a standard Web browser (such as Microsoft
TM
Internet Explorer).
Assigning the V7111 IP Address
applies equally to MGCP, H.323 and SIP.
Assigning the V7111 IP Address
To assign an IP address to the V7111 use one of the following methods:
Assigning an IP Address Using HTTP
HTTP using a Web browser (see
).
BootP (see
Assigning an IP Address Using BootP).
Voice Menu using a standard touch-tone telephone connected to one of the FXS analog
ports (see
Assigning an IP Address Using the Voice Menu Guidance). This method
doesn’t apply to FXO gateways.
The embedded Command Line Interface (CLI) accessed via Telnet or RS-232 (see
Assigning an IP Address Using the CLI).
DHCP (refer to the product’s User’s Manual).
The default networking parameters are show in
Table 9.
Use the ‘Reset’ button at any time to restore the V7111 networking parameters to their
factory default values (see
Restoring Networking Parameters to their Initial State).
3Com VCX V7111 Analog Gateway Installation Guide 25