18.0
Pump Control Switch
4. Turn the pump switch to AUTO.
The pump uses the Proximity Sensors inside the inlet hopper
to indicate when liquid treatment dispersion to the treater
should begin and will stop the pump as soon as the seed level
in the seed hopper is lower than the proximity sensor.
The Product Flow Light below the Drum Speed Dial will turn
on to indicate that seed is owing past the sensors.
Product Flow Light
Drum Speed Dial
5. Fine tune the drum rotation
by increasing or decreasing the Drum Speed Dial to get the
best possible coverage and the maximum volume.
WARNING:
Never stop the drum full of seed, unless it is an
emergency.
Staring the drum when it is full of seed can cause overloads
that may stress electrical components. Clean out as much
seed as possible BEFORE restarting the drum.