Panel Outputs [1.1]
Outputs 1 - 3 on the control panel and remote
keypad outputs 5 - 8 can be programmed to any
of the output types shown on pages 24 to 26. In
addition, all panel outputs can be inverted, see
“Configuration option 14” on page 32.
Programmable Output Types
No Type/Description
000 Bell On
Activates when the main Bell trigger is on and
deactivates at the end of the Bell Duration
time or when the alarm is cancelled by the
user.
001 Strobe On
Activates when the Strobe trigger is on, and
deactivates when the alarm is cancelled by
the user.
002 Switch 12V
Activates when the system is set and
deactivates when an alarm occurs or the
system is unset. This output is normally used for
latching detectors.
003 Detector Reset
Normally active at all times and deactivates
for 3 seconds when a valid passcode is
entered prior to setting the system. This output
is normally used for detector that required
power to be removed in order to reset them,
e.g., smoke detectors.
004 Walk Test
Activates when the "Walk Test" option is
selected and deactivates when the "Walk Test"
option is finished.
005 Alarm
Activates when an intruder alarm is detected
and deactivates when the alarm is reset or
aborted.
006 P.A.
Activates when a PA alarm is detected and
deactivates when the alarm is reset.
007 Fire
Activates when a Fire alarm is detected and
deactivates when the alarm is reset.
008 System Set
Act ivates wh en an y wa rd is se t an d
deactivates when the system is fully unset.
009 Code Accepted
Activates for 10 seconds following entry of any
valid passcode.
010 24 Hour
Activates when a 24Hr alarm is detected and
deactivates when the alarm is reset.
24
Engineer’s Menu 1 TS690R Installation Manual
Enter new output type
Type No.
1
Enter output No. 1 - 8
e.g. 1
e.g. 021
E / MENU 1
PANEL -
004
021
Panel Outputs Flowchart