4. SYSTEM DIAGRAM
The typical connection diagram for the entire PV system is shown in the
following fi gure.
1. PV-Panel: Provide DC power to Protect PV inverter
2. Protect PV PV-Inverter Converts DC (Direct Current) power from
PV panel(s) to AC (Alternating Current) power. Because Protect PV is
grid-connected it controls the current amplitude according to the PV
Panel power supply. Protect PV always tries to convert the maximum
power from your PV panel(s).
3. Connection system: This “interface” between Utility and PV-Inverter-
may consist of electrical breaker, fuse and connecting terminals. To
comply with local safety standards and codes, the connection system
should be designed and implemented by a qualifi ed technician.
4. Utility: Referred to as “grid” in this manual, is the way your electric
power company provides power to your place. Please note that
Protect PV can only connect to low-voltage systems (namely, 220,
230VAC, 50/60Hz).