Antari Lighting and Effects HZ-350 Work Light User Manual


 
5
Note: Transmitter registration must be completed within 15 seconds or HZ-350 has to be
power on again for next registration.
LCD CONTROL OPERATION
After transmitter(s) registration time ends, LCD screen will then show Ready To Haze”.
Now the machine is ready for operating.
FUNCTIONS SETTING
Press Menu button for setting different functions per sequence as below.
Interval Set To set the interval time under timer mode by pressing Up/Timer and
Down/On buttons (5 to 200 seconds).
Duration Set To set the duration time under timer mode by pressing Up/Timer and
Down/On buttons (5 to 200 seconds).
DMX512 Add. To set the DMX channel under DMX control mode by pressing Up/Timer
and Down/On buttons (1 to 512 channels).
Wireless ON To activate/terminate the wireless control system by pressing Up/Timer
and Down/On buttons (ON/OFF). When wireless control system is
activated, letter “W” will be showed under main screen display “Ready To
Haze”. Once the wireless control system is terminated then the letter “W”
will disappear accordingly.
Quick Start To activate/terminate quick start function by pressing Up/Timer and
Down/On buttons (ON/OFF). Once Quick Start function is on, the
output job under timer or continuous output (LCD/W-1/DMX) mode
terminated by power off will be directly resumed after power on again.
When the unit is power off not under output mode then the LCD screen will
resume to “Ready To Haze” main screen display directly.
Ready To
Haze