Electric cabinet should be cleaned from dust and shaving with air once in six months.
If clamp pistons do not press the profile, pressure should be controlled and adjusted
from the conditioner.
Machine needs at least 6 bar (90 psi) air pressure. Make sure to maintain this.
VII – TABLE OF PROBABLE PROBLEMS AND
THEIR SOLUTIONS
VII.1 - WHEN PROBLEM OCCURS, THE PROCESSES THAT
SHOULD BE DONE
VII.2 TROUBLESHOOTING
PROBLEM POSSIBLE REASON SOLUTION
No movement
Electrical failure
Failure of air connection
Check the safety power switch,
fuses, entry phases and air
connections.
Motors do not run
Electrical failure
Check the safety power switch,
fuses, entry phases, frequency
converter, (4), (7) numbered
buttons and thermic.
Look at frequency converter
Motor run but triple
drilling edges do not
turn
Triple drilling head is
broken
Call service person.
Drill is not working
properly. It drills hardly
Drill edges become
blunt.
It is changed with new one.
Clamping pistons do not
run
Failure of air connection
Valve failure
Check the air connections.
Check the valve.