Atech Tech LIBRA-02 HM Router User Manual


 
19
Operating and Safety Instructions
9.3 In order to prevent that the water inside the air system causes damage to the
pneumatic system components, the conditioner unit collects the water in the collection
receptacle. Discharge the collected water periodically (at the end of the working day)
by pressing the button under the cylinder depot of the conditioner.
9.4 The manufacturer recommends to use the following oils with the conditioner: TELLUS
C 10 / BP ENERGOL HLP 10/ MOBIL DTE LIGHT / PETROL OFISI SPINDURA 10.
10. MAINTENANCE
10.1 PERIODIC CONTROLS AND MAINTENANCE AT THE END OF THE WORKING DAY
10.1.1 Unplug the machine first.
10.1.2 Check the oil level of the conditioner, which lubricates the pneumatic system,
before starting to operate the machine. The oil level decreases with the time. You can
refill oil by opening the oil filling cap of the cylinder depot manually or with a key.
10.1.3 Check the router bit for its proper function at each operation. Replace damaged
router bit.
10.1.4 If you have used water or water based liquids during drilling operations, dry the
machine with a dry cloth after the operation is finished. If the machine will not be used
for a long time, lubricate the unpainted sections of the machine as protection against
corrosion.
10.1.5 Remove all burr, foreign materials from the machine’s surface.
10.1.6 When cleaning the machine, don’t use any materials which could cause damage
to the machine’s paint.
11. INFORMATION ABOUT FAULTY USE
11.1 Check the plug for power supply.
11.2 Keep the button pressed for continuous turning of the router bit.
11.3 Ensure that the rotation direction of the router bit and the triple drilling unit is correct
(see the turning direction labels on the machine).
11.4 Do not start working the profile before the pneumatic clamps have clamped the
profile properly.
11.5 This machine is used for opening of slots, channels in various dimensions onto PVC,
aluminum profiles and wooden materials.