Installation (Continued)
LUBRICATION
THIS UNIT CONTAINS NO OIL. Before operating
compressor, fill to the center of the sight gauge
(see Figure 14).
Using any other type of oil may shorten pump
life and damage valves.
Recommended Oil (2 Options)
• SingleviscositySAE30ISO100non-detergentcompressor
oil� Available from Campbell Hausfeld, part number
ST126700AV.
• 10W30syntheticoilsuchasMobil1
®
Oil Capacity
CE7000 Series� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �2 quarts
CE8000 Series� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �4 quarts
CE9000 Series� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4-1/2 quarts
Fill the pump with oil to the center of the sight gauge using oil
fill opening (see Figure 14)� Do NOT fill the pump through the
breather cap opening as this may cause oil to leak and spray
out during operation.
The Automotive Series compressor models include a low oil
guard� This device monitors the oil level in the crankcase
and will shut off the compressor if the oil level gets too low�
See separate low oil guard manual for complete operating
instructions�
NOTE: Some residual oil may still be in the pump from factory
testing leaving a thin coat on the sight gauge; however, there is
not enough oil to operate the unit�
Figure 14
Breather Cap
Oil Drain Plug
Oil Drain Plug
Oil Fill Plug
Oil Fill Plug
SIGHT GAUGE
Full
Low