Campbell Hausfeld CE7000 Air Compressor User Manual


 
Operating Instructions
www.CH-Commercial.com
Troubleshooting Guide for Units in Service for a Period of Time (Continued)
SYMPTOM CAUSE SOLUTION
Milky oil in crankcase Low usage of compressor -
water is condesing in the
crankcase
Run the compressor continuously for 1 hour� The heat generated during
this running period will evaporate the moisture out of the oil�
Wrong type of oil DonotuseSAE-30automotivetypeoil.Usingthewrongoilcancause
various problems with the pump and will void the warranty� Only use
the oils that the operating manual recommends�
Improper environment Unit should not be installed in a poorly vented area or exposed to
extreme cold or hot conditions� Normal operating range should be
between 32°F and 100°F�
Rotation incorrect Check to make sure the compressor is running the direction of the
flywheel arrow� Air flow should be so that the flywheel directs air across
the head of the pump� Standing in front of the compressor (non-belt
guard side) air should flow back to front�
Slight leakage of tank check
valve
Aircoolsandcondensates,thenleaksbackintothepump.Draining
tank of air after use will normally take care of this situation�
Pressure switch
continually blows air out
the unloader valve
Defectivecheckvalve Replace check valve�
Pressure switch does
not release air when the
compressor shuts off�
Pressure switch unloader not
working properly
Drainthetankofallpressure.Restartcompressorundernoload.If
compressor is able to start, then the unloader needs to be checked�
If this problem is not corrected it will fail the motor and / or other
electrical components�
Compressor will not
shut off
Defectivepressureswitch Settingtoohigh.Ifadjustingthesettingdoesnotwork,replacepressure
switch�
Defectivesafetyvalve Make sure tank pressure gauge is reading correctly and if necessary
replace tank safety valve
Unit vibrates excessively Loose fasteners This includes mounting bolts for the pump, motor, belt guard, mag�
starter, etc� Check for loose fasteners as part of a routine maintenance
schedule� Tighten any loose fasteners�
Loose pulley, loose belt or
misalignment or pulleys
The pulley and belt may need to be tightened over time� The pulleys
may need to be realigned to assure proper belt wear and lower
vibration� These should be checked as part of regular maintenance�
Defectivepump A defective pump includes knocking or making noises not normal to
the pump design� Severe oil out the breather usually indicates ring or
cylinder wear� Low pump performance could indicate valve problems�
There are numerous symptoms associated with a defective pump� The
pump will need to be evaluated�
Water in discharge air Hot humid weather Duringhotandhumidweatheritisnormaltoaccumulatewaterinthe
compressor tank� This is normal and requires frequent draining of tank�
We recommend use of an automatic drain along with filters and dryers
if this is a problem�
Water accumulated in the
tank
Draintankofwatertopreventtankcorrosionandairtoolwear.Itis
recommended use of an automatic drain along with filters and dryer to
prevent water into exhaust air of the compressor�
Continued on next page
18