Operating Instructions
Troubleshooting Guide for New Installations (Continued)
SYMPTOM CAUSE SOLUTION
Unit runs very noisy Damagetothecompressor Check to make sure the compressor has not been damaged in the
shipping or installation� Make sure the belt guard was not damaged�
Beltguardshouldnotbemakingcontactwithflywheelorpulley.
Loose fasteners Check all bolts and nuts to assure they did not loosen during shipping�
Loose flywheel or pulley Check to assure pulley and flywheel are correctly tightened�
Improper installation If unit is left on skid it may cause excessive vibration� Remove unit from
skid and mount loosely to floor with vibration pads and anchor bolts�
Donottightenboltstight.Leavenutlooseapproximately1/8inchfrom
compressor foot�
Oil in discharge air or
out crankcase breather
Breakinperiod Some oil in the exhaust air is normal during the break-in period and
during heavy usage after the break-in period� Oil discharge should
reduce as hours are accumulated on the unit�
Wrong type of oil DonotuseSAE-30automotivetypeoil.Usingthewrongoilcancause
problems with the pump and will void the warranty� Only use the oils
that the operating manual recommends (see Lubrication section)�
Improper environment Unit should not be installed in a poorly vented area or exposed to
extreme cold or hot conditions� Normal operating range should be
between 32°F and 100°F�
Compressor seems to
run hot
Rotation incorrect Check to make sure the compressor is running the direction of the
flywheel arrow� Air flow should be so that the flywheel directs air across
the head of the pump� Standing in front of the compressor (non-belt
guard side) air should flow back to front�
www.CH-Commercial.com
16