Campbell Hausfeld SB524000 Nail Gun User Manual


 
5
SB524000
www.chpower.com
Operating The Tool
(Continued)
3. Use 1/4 inch air hoses
with a minimum
working pressure of
150 psi. Use 3/8 inch
air hoses for 50 foot
run or longer. For
better performance, install a 3/8 inch
quick plug (1/4 inch NPT threads)
with an inside diameter of .315 inch
(8mm) on the tool and a 3/8 inch
quick coupler on the air hose.
4. Use a pressure regulator on the
compressor, with an operating
pressure of 0 psi - 125 psi. A pressure
regulator is required to control
the operating pressure of the tool
between 70 psi and 120 psi.
SINGLE SEQUENTIAL MODE
This mode
requires the
trigger to
be pulled
each time
a fastener is driven. The tool can be
actuated by depressing the WCE against
the work surface followed by pulling
the trigger.
The trigger must be released to reset
the tool before another fastener can be
driven.
CHECKING THE WORK CONTACT
ELEMENT (WCE)
Check the operation
of the Work Contact
Element (WCE) trip mechanism before
each use. The WCE must move freely
without binding through its entire
travel distance. The WCE spring must
return the WCE to its fully extended
position after being depressed. Do
not operate the tool if the WCE trip
mechanism is not operating properly.
Personal injury may occur.
1. Disconnect the air
supply from the tool.
2. Remove all
fasteners
from the
magazine
(see Loading/
Unloading).
3. Make sure the trigger
and work contact
element (WCE) move
freely up and down
without sticking or
binding.
4. Reconnect
air supply
to the
tool.
5. Depress the Work
Contact Element
(WCE) against the
work surface without
pulling the trigger.
The tool MUST NOT
OPERATE. Do not use the tool if it
operates without pulling the trigger.
Personal injury may result.
6. Remove the tool from
the work surface.
The Work Contact
Element (WCE) must
return to its original
down position. The tool MUST NOT
OPERATE. Do not use the tool if it
operates while lifted from the work
surface. Personal injury may result.
7. Pull the
trigger
and
depress
the work
contact
element (WCE) against the work
surface. The tool MUST NOT
OPERATE.
8. Depress
the Work
Contact
Element
(WCE)
against the work surface. Pull the
trigger. The tool MUST OPERATE.
Recommended Hookup
150 psi WP
3/8 inch I.D.
Quick Plug
Quick
Coupler
Air Hose
Quick Plug
(Optional)
Quick
Coupler
(Optional)
Regulator
Lubricator
Filter