Campbell Hausfeld SB524000 Nail Gun User Manual


 
7
SB524000
www.chpower.com
Maintenance
TOOL REPAIR
Only qualified personnel should repair
the tool, and they should use genuine
Campbell Hausfeld replacement parts
and accessories, or parts and accessories
which perform equivalently.
ASSEMBLY PROCEDURE FOR SEALS
When repairing a tool, the internal
parts must be cleaned and lubricated.
Parker O-lube or equivalent must be
used on all o-rings. Each o-ring must be
coated with O-lube before assembling.
A small amount of oil must be used on
all moving surfaces and pivots.
After reassembling, a few drops of 30W
non-detergent oil or equivalent, must
be added through the air line before
testing.
Storage
The unit should be stored in a cool, dry
place.
TECHNICAL SUPPORT
Please call our Tool Hotline at 1-800-
543-6400 with any questions regarding
the operation or repair of this tool or
for additional copies of this manual.
FASTENER AND REPLACEMENT
PARTS
Use only genuine
Campbell Hausfeld
18 gauge fasteners (or equivalent - see
Fastener Interchange Information).
Tool performance, safety and durability
could be reduced if improper fasteners
are used. When ordering replacement
parts or fasteners, specify by part
number.
Notes