Chauvet 250 Work Light User Manual


 
Page 16 of 20 Intimidator™ Spot LED 250 User Manual Rev. 11
Password
Channel
The IntimidatorSpot LED 250 contains a password-protected mode which allows you
to calibrate and troubleshoot any small issues you may have during normal operation.
In order to access this mode, do the following:
1. Press and hold <MODE/ESC> for at least 10 seconds.
2. Use the <UP> and <DOWN> buttons to enter the password: 2323.
3. Press <ENTER>.
In this mode you have several options for adjustment.
Parameter Programming Steps Description
Pan Adjust P128 Manually adjust the pan angle
Tilt Adjust t128 Manually adjust the tilt angle
Gobo Wheel Adjust G128 Manually adjust the gobo wheel
Color Wheel Adjust C128 Manually adjust the color wheel
Prism Adjust L128 Manually adjust the prism
Lamp Brightness Adjust d000
Manually adjust the starting
brightness of the lamp
Pan Switch Strength P--0 Adjust the strength of pan switch
Tilt Switch Strength t--0 Adjust the strength of tilt switch