4. OPERATING INSTRUCTIONS
Using the Control Panel
Access control panel functions using the four buttons located directly underneath the LED display on the
included wired remote.
BUTTON
FUNCTION
<MODE
ESC>
Used to scroll through the current
operating mode, as well as back out of
the current menu option
<DOWN>
Used to select decreasing advancement
in the value
<UP>
Used to select increasing advancement
in the value
<ENTER>
Used to select a value and store it to
memory
Use the control panel to select the operating mode, as well as the sub-features. For a detailed layout of the
control panel functions, please see the “menu map” section on the previous page.
Menu Map
Menu Programming Steps Description
DMX Mode
d001
d001~512 DMX starting address
Standalone Mode NASL
NASL
SLAu
SoN
Standalone: Slave receive mode
NStS
SrUn
Standalone: Slow
NAFA
FASt
Standalone: Sound-active
Pan Invert PAN rPAN Pan invert
Tilt Invert tit rtit Tilt invert
Display Invert diS rdiS Invert the display
DMX Personality 11CH
8CH
8-channel DMX personality
11CH
11-channel DMX personality
Reset rESt
Reset all motors to correct any errors with
motors misaligning during operation
Load Default LoAd
Revert all settings back to the factory
default
Configuring the Starting Address
The Intimidator™ Scan LED 300
fixture uses up to 11 DMX channels. In this DMX configuration/personality,
the highest channel that the fixture may be set to in order to function properly is 502. Any address higher
than this will prevent access to all of the channels, while in this mode; however, if you desire to use one of
the other DMX channels configurations (personalities), please consider the total DMX channels when
selecting a DMX address.
The Intimidator™ Scan LED 300 fixture uses 8 or 11 DMX channels, depending on the selected DMX
configuration (personality).