Installing the Particle Tray
1. Unlock the Table Lock Lever. Lift and turn the
Toggle Table Stop so that its slot aligns with the Table.
2. Pull the Table to the front of the Water Tray Frame.
3. Slide the Particle Tray into the Grooves
on the underside of the Table.
4. Return the Table to its working position,
and lift then turn the Toggle Table Stop
so that its slot aligns sideways.
Figure F: Particle Tray
Particle Tray
Grooves
Table
Water Tray and Pump Setup
1. From the right side of the saw, place the
Water Tray (drain plug end to the left) on the
lip at the bottom of the Water Tray Frame.
2. Slide the Water Tray in under the Table
until it rests in place within the tabs.
3. Adjust the flow control on the
Pump to the desired level.
4. Place the Pump into the Pump Bracket in the
Pump Basin. It should fit securely into the Bracket.
5. Connect the clear water Hose from under the arm of
the Motor Head to the Hose Connector on the Pump.
6. Make sure your hands are dry and the Tile Saw
is unplugged, then attach the Pump Power
Cord to the Pump Outlet on the Motor Head.
7. Fill the Water Tray with clean water up to the
Fill Rim (see Figure H) before every use.
Figure G: Water Tray Installation
Water Tray
Water Tray
Frame
Figure H: Pump setup
Water
Tray
Drain Plug
Fill Rim
Pump
Pump
Basin
Pump
Power
Cord
Pump
Outlet
Hose Connector