Chicago Electric 96448 Impact Driver User Manual


 
Page 8SKU 96448 For technical questions, please call 1-800-444-3353.
3-Prong Plug and Outlet
Outlets for 2-Prong Plug
Double Insulated Tools: Tools with Two Prong Plugs
Tools marked “Double Insulated” do not require grounding. They have a special 1.
double insulation system which satises OSHA requirements and complies with
the applicable standards of Underwriters Laboratories, Inc., the Canadian Stan-
dard Association, and the National Electrical Code.
(See Outlets for 2-Prong Plug.)
Double insulated tools may be used in either of the 120 volt outlets shown in the 2.
preceding illustration. (See Outlets for 2-Prong Plug.)
Extension Cords
Grounded1. tools require a three wire extension cord. Double Insulated tools can
use either a two or three wire extension cord.
As the distance from the supply outlet increases, you must use a heavier gauge 2.
extension cord. Using extension cords with inadequately sized wire causes a
serious drop in voltage, resulting in loss of power and possible tool damage.
(See Table A.)
The smaller the gauge number of the wire, the greater the capacity of the cord. 3.
For example, a 14 gauge cord can carry a higher current than a 16 gauge cord.
(See Table A.)
When using more than one extension cord to make up the total length, make 4.
sure each cord contains at least the minimum wire size required. (See Table A.)
If you are using one extension cord for more than one tool, add the nameplate5.
amperes and use the sum to determine the required minimum cord size.
(See Table A.)
If you are using an extension cord outdoors, make sure it is marked with the suf-6.
x “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.