To Add Oil
Drain tank to
release air pressure
before removing the oil fill cap or
oil drain plug.
1. Place unit on a level surface.
2. Remove oil fill plug (A) and
slowly add compressor oil until
it is even with the top of the oil
fill hole. NOTE: Do not allow oil
to be lower than 3/8" (6 threads)
from the top at any time. When
filling the crankcase, the oil flows
very slowly into the pump. If the
oil is added too quickly, it will
overflow and appear to be full.
12- ENG
A09713
A
INSTALLATION
GROUNDING INSTRUCTIONS
RISK OF
ELECTRICAL
SHOCK. In the event of a short
circuit, grounding reduces the risk
of shock by providing an escape
wire for the electric current. This
air compressor must be properly
grounded.
Grounding Pin
Grounded
Outlets
Plug
The portable air compressor is
equipped with a cord having a
grounding wire with an appropriate
grounding plug (see following
illustrations). The plug must be used
with an outlet that has been installed
and grounded in accordance with all
local codes and ordinances.
1. The cord set and plug with this
unit contains a grounding pin.
This plug MUST be used with a
grounded outlet.
IMPORTANT:
The outlet being used
must be installed and grounded in
accordance with all local codes and
ordinances.
2. Make sure the outlet being used
has the same configuration
as the grounded plug.
DO
NOT USE AN ADAPTER.
See
illustration.
NOTE:
Crankcase oil capacity is
approximately 16 fluid ounces.
3. Replace oil fill plug.
Location of the Air Compressor
Locate the air compressor in a
clean, dry and well ventilated area.
The air compressor should be
located at least 12" away from the
wall or other obstructions that will
interfere with the flow of air. The
air compressor pump and shroud
are designed to allow for proper
cooling. The ventilation openings
on the compressor are necessary
to maintain proper operating
temperature. Do not place rags or
other containers on or near these
openings.