Craftsman 919.195411 Air Compressor User Manual


 
4. Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
5. Lift retaining clip from handle and
remove handle.
6. Using an adjustable wrench,
rotate the pressure switch
assembly as shown.
7. Remove the outlet pressure
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
8. Remove the regulator.
21- ENG
A09713
Motor
This motor has a manual thermal
overload protector. If the motor
overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed
to cool down before restarting. To
restart:
1. Place the On/Auto/Off lever in
the "Off" postion.
2. Allow the motor to cool.
3. Depress the red reset button on
the motor.
4. Place the On/Auto/Off lever in
the "On/Auto" postion to restart
the motor.
Pressure Switch - Replacement
Risk of Bursting.
Pressure loads
beyond design limits may cause
tank rupture or explosion. Pressure
switch operation is related to
motor HP, tank rating, and safety
valve setting. Do not attempt
to adjust, remove, or defeat the
pressure switch, or change and
modify any pressure control related
device. If replacement is necessary
the same rated switch must be
used. Contact a trained service
technician for replacement.
To Replace Regulator
1. Release all air pressure from air
tank. See "To Drain Tank" in the
"Maintenance" section.
2. Unplug air compressor.
3. Remove the regulator ring and
remove the console cover.
Regulator
Ring
Cover
Outlet
Pressure
Gauge
Regulator
Tank
Pressure
Gauge
Retaining clip
Handle
Quick
Connect
Reset
Button