14 - ENG
TROUBLESHOOTINGGUIDE
MANY COMMON PROBLEMS CAN BE SOLVED EASILY BY UTILIZING THE
CHART BELOW. FOR MORE SERIOUS OR PERSISTENT PROBLEMS, CONTACT
A D
e
WALT SERVICE CENTER OR CALL 1-(800)-4-D
e
WALT (1-800-433-9258).
WARNING: To reduce the risk of serious personal injury, ALWAYS disconnect air
from tool and engage trigger lock, before all repairs.
SYMPTOM PROBLEMS SOLUTIONS
Air leak near top of
tool or in trigger area
Loose screws. Tighten screws.
Worn or damaged
o-rings or seals.
Install Overhaul Kit.
Tool does nothing or
operates sluggishly
Inadequate air supply. Verify adequate air supply.
Inadequate lubrication. Put 5 or 7 drops of
oil into air inlet.
Worn or damaged
o-rings or seals.
Install Overhaul Kit.
Air leak near
bottom of tool
Loose screws. Tighten screws.
Worn or damaged
o-rings or bumper.
Install Overhaul Kit.
Tool jams frequently Incorrect fasteners. Verify approved fasteners
of correct size and 15°
collation angle.
Damaged fasteners.
Bent collation wire.
Replace with undamaged
fasteners.
Canister or nose screws loose Tighten screws.
Canister is dirty. Clean magazine.
Driver tip is worn or damaged. Install Driver Maintenance Kit.
Other Contact a D
e
WALT Authorized
Warranty Service Center
TOOL SPECIFICATIONS
DWFP12658
Height (inch/mm) 10.5/ 266
Width (inch/mm) 4.3/ 110
Length (inch/mm) 10.3/ 262
Weight (lbs/kg) 4.91/ 2.23
Recommended Operating Pressure 70-120 psi (4.8 to 8.3 bar)
Air Consumption per 100 cycles
4.13 CFM
Loading capacity 120 nails