Earlex HV5500US Paint Sprayer User Manual


 
8
Questions? Call toll free: 888-783-2612
The turbine unit only requires minimal maintenance
Ensure its filter (28) element is kept clean at all times.
This is the filter underneath the main body of the turbine. Disconnect the unit from the power supply, turn on side and remove foam material. This
can be washed out if necessary and replaced when dry. From time to time this filter will need replacing (part no.L0058).
The turbine bearings are sealed and lubricated for life. There is no maintenance or adjustment required.
Clean the turbine and hose unit with a damp cloth after use.
The hose is stowed by coiling it between the motor housing and hose cover.
The power cord is stowed by wrapping around the base of the unit and locating the plug in the space at the back of the unit.
Gland washers (16) prevent leakage of air passing the needle. This leakage reduces the performance of the spray gun and must, therefore, be kept
to a minimum. After a period of use the gland washers will wear. This is normal and can be compensated by gradual adjustment of the gland nut (15).
Periodically check to ensure the gland nut is not loose. DO NOT OVER-TIGHTEN as this will increase wear of the washers. When necessary just
tighten the nut lightly using the special spanner (27) provided.
By tightening this nut, the inside diameter of gland washers reduce thereby closing any small gap that may have occurred between the needle and
gland washers, therefore, eliminating excessive leakage.
PROBLEM CAUSE ACTION REQUIRED
The paint runs on the item
being sprayed
Paint too diluted Add undiluted material
Paint volume too high Reduce the paint flow by adjusting
screw (12)
Moving too slowly Increase speed of application
Gun trigger being held for too long Release trigger earlier
Gun too close Increase the distance between gun and
workpiece
Paint is thin or irregular Paint too diluted Add undiluted material
Paint volume too low Increase the paint flow by adjusting
screw (12)
Moving too fast Reduce speed of application
Gun clogged Clean the gun
Gun too far away Reduce the distance between gun and
workpiece
No paint being produced Paint too thick Add thinner
Gun clogged Clean the gun
Pick up tube clogged Clean pick up tube (24)
Air hose split Replace air hose
Grainy paint Filter the paint
Container almost empty Refill container
Gun at an angle Ensure pick up tube is angled towards
paint
Air intake blocked Check no paper or loose debris can
block the air intake underneath the unit
TROUBLESHOOTING
PERIODIC MAINTENANCE
TURBINE UNIT
L1325_5500_0311.qxd:Layout 2 7/3/11 17:00 Page 8