Emerson 350 Laser Level User Manual


 
Section
6
Transmitter Specifications
6.1 Hazardous Locations /
General Ratings
CSA and CSAUS: Explosion Proof:
Class I Div. 1 or 2, Grps. B, C, D
Class II, Grps. E, F, G
Class III
T
amb
-40°C to 85°C (-40°F to 185°F)
ATEX: Ex d:
Sira 10ATEX1308X
Ex d IIC T5 Gb
Ex tb IIIC T100°C IP66 Db
T
amb
-40°C to 85°C (-40°F to 185°F)
0344 II 2GD
IECEx: Ex d:
IECEx SIR 10.0150X
Ex d IIC T5 Gb
Ex tb IIC T100°C IP66 Db
T
amb
-40°C to 85°C (-40°F to 185°F)
6.2 Electronic Specifications
Supply Voltage: 13 – 36 Vdc (13V @ 20mA)
Repeatability:
.005% of full scale or
.010”, whichever is greater
Non-Linearity: .01% of full scale or .030”,
whichever is greater
Sensor Accuracy: .01% of full scale or .030”,
whichever is greater
Damping: 1 to 26 seconds
Operating Temp: -50 to 85 C
(-58 to 185 F)
Housing: Explosion proof, dual compartment,
½”npt conduit, epoxy coated
aluminum; NEMA 4X, 7
Humidity Limits: SAMA PMC 31.1-5.2
Vibration Limits: SAMA PMC 31.1-5.3
RFI Limits: SAMA PMC 31.1-
20 to 1000 MHz
Up to 30 V/m
6.3 Sensor Probe Specifications
Material: 5/8” 316ss standard, optional:
Hastalloy, Monel, or Kynar sleeved
Operating Temperature: -50 to 149 C
(-58 to 300 F)
Maximum Pressure: 2000psig @ 300F
Range: 12 in. to 30 ft.
14